Features
product code
A-UC-AST-PHG701I
color display with touch panel
7"
independent treatment channels
3
intensity regulation in the patient circuit for both channels simultaneously or separately
electrode test
manual mode
disease entities selected by name or medical field
preset treatment programs database
preset treatment sequences database
possibility of creating user programs
user sequence database
favorite programs
possibility of program names and user sequences edition
encyclopedia describing the treatment methodology
statistics of performed treatment procedures
buzzer sound volume regulation
battery
Electrotherapy
operation in CC (current stabilization) or CV (voltage stabilization) modes
full galvanic isolation between channels in each mode
Currents and methods
interferential isoplanar
interferential dynamic
interferential single channel AMF
TENS symmetric
TENS asymmetric
TENS alternating
TENS burst
TENS for spastic paralysis therapy
Kotz' current (Russian stimulation)
tonolysis
diadynamic (MF, DF, CP, CP-ISO, LP)
pulsed rectangular
pulsed triangular
pulsed UR according to Trabert (2 - 5)
pulsed according to Leduc (1 - 9)
pulsed neofaradic (1 - 19)
unipolar sine surge
galvanic
microcurrents
Ultrasound therapy
waterproof ultrasound heads
continuous / pulse emission
ultrasound head contact control (effective treatment time measured)
head sensitivity calibration according to the needs
Combined therapy
operation in CC (current stabilization) or CV (voltage stabilization) modes
Currents and methods
interferential single channel AMF
TENS symmetric
TENS asymmetric
TENS alternating
TENS burst
Kotz' current (Russian stimulation)
Laser therapy
operation with applicators: scanning laser, cluster laser and point probes
emission mode: continuous and pulse
adjustment of laser radiation power
duty factor
automatic laser radiation power test
automatic calculation of time relative to treatment parameters - dose, power, duty factor, treatment area
three modes of treatment field irradiation in scanning laser applicators
dedicated modes for cooperation with optical fiber applicators
optical fiber applicators for laserpuncture and ENT applications
pilot beam indicating the application site
Magnetotherapy
continuous and pulse emission
field shape: sine, triangle, rectangle, half-sinus, half-triangle, half-rectangle
optional operation with one or two plate CPE applicators
convenient application of applicators with straps and velcro belts
Preset treatment programs
built-in treatment programs, including:
420
built-in treatment programs for electrotherapy
69
built-in treatment programs for ultrasound therapy
58
built-in treatment programs for combined therapy
77
IR point probe programs
39
R point probe programs
18
programs with Nogier frequency
8
programs with Voll frequency
30
cluster laser applicator programs
54
program sequences for scanning laser applicators
26
built-in treatment programs for magnetotherapy
41
user-defined programs – electrotherapy
50
user-defined programs – ultrasound therapy
50
user-defined programs – combined therapy
50
user-defined programs – biostimulation laser therapy
50 (for each applicator)
user-defined programs – magnetotherapy
50
favorite programs
Preset treatment sequences
built-in treatment sequences for electrotherapy
38
user-defined sequences
10
Electrotherapy technical parameters
max. current intensity in the patient circuit (CC mode)
galvanic
40 mA
diadynamic, impulse
60 mA
interferential, Kotz' current
100 mA
unipolar sine surge
100 mA
TENS
140 mA
tonolysis
100 mA
microcurrents
1000 uA
max. voltage amplitude in the patient circuit (CV mode)
140 V
treatment timer
30 s - 60 minutes
Ultrasound therapy technical parameters
operating frequency
1 & 3,5 MHz
effective radiation area
1 cm², 4 cm²
maximum ultrasound wave intensity
2/3 W/cm²
frequency in pulse mode
16 Hz, 48 Hz, 100 Hz
duty factor in pulse mode
5 - 75%, step 5%
treatment timer
30 s - 30 minutes
Laser therapy technical parameters
laser device class
3B
treatment timer
1 s - 100 minutes
Laser therapy parameters - biostimulation laser point probes
red light laser point probes wavelength
660 nm
maximum power of the red light point probes
80 mW
infrared laser point probes wavelength
808 nm
maximum power of the infrared point probes
400 mW
power regulation
25%, 50%, 75%, 100%
pulse mode frequency
1 - 5000 Hz
duty factor in pulse mode
10 - 90%, pulse 50 us
Laser therapy parameters - scanning laser applicator
scanning laser applicator wavelength
808 & 660 nm
maximum power of the scanning laser applicator
450 & 100 mW
power regulation
50%, 100%
pulse mode frequency
1 - 5000 Hz
duty factor for scaning laser applicator pulse mode
75%
Laser therapy parameters - cluster laser applicator
cluster laser applicator wavelength
4x 808 nm & 5x 660 nm
maximum power of the cluster laser applicator
4x 400 mW & 5x 40 mW
power regulation
50%, 100%
pulse mode frequency
1 - 5000 Hz
duty factor in pulse mode
10 - 90%, pulse 50 us
Magnetotherapy technical parameters
maximum magnetic field induction
10 mT
operating frequency
2 - 120 Hz
interval mode parameters
pulse 1 s / break 0,5 - 8 s
treatment timer
30 s - 30 minutes
General technical parameters
dimensions
34 x 28 x 11-16 cm
weight
6 kg
battery type
Li-lon
battery capacity
2250 mAh
power supply, power consumption
230 V, 50/60 Hz, 75 W, 90 VA