Features
product code
A-UL-AST-PLL
color display with touch panel
5"
independent treatment channels
1
manual mode
disease entities selected by name or medical field
preset treatment programs database
possibility of creating user programs
favorite programs
possibility of program names edition
encyclopedia describing the treatment methodology
treatment statistics
buzzer sound volume regulation
STAND BY mode
battery (optional accessory)
battery saving mode (option)
Laser therapy
operation with applicators: scanning laser, cluster laser and point probes
emission mode: continuous and pulse
adjustment of laser radiation power
duty factor
possibility of automatic treatment procedure repetition
automatic laser radiation power test
automatic calculation of time relative to treatment parameters - dose, power, duty factor, treatment area
three modes of treatment field irradiation in scanning laser applicators
dedicated modes for cooperation with optical fiber applicators
optical fiber applicators for laserpuncture and ENT applications
pilot beam indicating the application site
Preset treatment programs
preset treatment programs, including:
175
IR point probe programs
39
R point probe programs
18
programs with Nogier frequency
8
programs with Voll frequency
30
cluster laser applicator programs
54
program sequences for scanning laser applicators
26
user-defined programs – biostimulation laser therapy
50 (for each applicator)
favorite programs
Laser therapy technical parameters
laser device class
3B
treatment timer
1 s - 100 minutes
Laser therapy parameters - biostimulation laser point probes
red light laser point probes wavelength
660 nm
maximum power of the red light point probes
80 mW
infrared laser point probes wavelength
808 nm
maximum power of the infrared point probes
400 mW
power regulation
25%, 50%, 75%, 100%
pulse mode frequency
1 - 5000 Hz
duty factor in pulse mode
10 - 90%, pulse 50 us
Laser therapy parameters - scanning laser applicator
scanning laser applicator wavelength
808 & 660 nm
maximum power of the scanning laser applicator
450 & 100 mW
power regulation
50%, 100%
pulse mode frequency
1 - 5000 Hz
duty factor for scaning laser applicator pulse mode
75%
Laser therapy parameters - cluster laser applicator
cluster laser applicator wavelength
4x 808 nm & 5x 660 nm
maximum power of the cluster laser applicator
4x 400 mW & 5x 40 mW
power regulation
50%, 100%
pulse mode frequency
1 - 5000 Hz
duty factor in pulse mode
10 - 90%
General technical parameters
dimensions
25 x 27 x 16,5 cm
device weight
3 kg
battery type (option)
Li-ion
battery capacity (option)
2100 mAh
power supply, power consumption