PhysioGo.Lite Laser

discover new
biostimulation laser

PhysioGo.Lite LASER

Safe therapy and comfort of use

PhysioGo.Lite Laser is the latest low level laser therapy device in the offer of ASTAR company. Its unique design and applied protection concepts ensure patient safety during therapy. The compact size of the laser makes it an excellent choice for physiotherapists carrying out therapy in various offices or specialising in sports medicine.

Discover why the PhysioGo.Lite Laser unit is so often chosen on the market of low level biostimulation lasers.

Benefits for the patient

Laser applicators – huge therapeutic possibilities

Clinical studies and years of experience in the field of laser therapy applications have demonstrated the effectiveness of this therapy for the appropriate wavelengths. The so-called “therapeutic window” has been defined. It is a range of wavelengths from 650 nm to 1200 nm.

 

The PhysioGo.Lite Laser is compatible with all laser applicators offered by ASTAR, i.e. point probes, scanning applicator and shower applicator. It uses two wavelengths – 660 nm (R) for superficial effects and 808 nm (IR) for deeper tissue therapy. In addition to the wavelength, the power of the applicator is also an important parameter. The maximum power available to the therapist when using the shower applicator is as much as 1800 mW available from five infrared (IR) and four red light (R) laser diodes.

 

In addition, the use of the scanning applicator makes it possible to carry out treatments on large areas with simultaneous application of R and IR radiation.

 

Up to three different laser sources can be connected to the unit simultaneously.

Safety first – self-test procedure and more

The device software allows you to perform the self-test procedure each time it is turned on. It is a current control of the device’s operational status, thanks to which PhysioGo.Lite Laser is a safe tool in the hands of a physiotherapist. Once the self-test is completed, the display indicates that the applicators connected to the device are ready for operation. A radiation power test function for laser applicators is available on the device. The PhysioGo.Lite Laser complies with the requirements of the European Parliament and Council Regulation (EU) 2017/745 (MDR).

 

Medical devices require annual periodic inspections. To meet these requirements, PhysioGo.Lite Laser gives the opportunity to save the date of the next inspection review. After the deadline, the device will automatically remind the user to carry out the necessary inspection.

Benefits for the therapist

Activity support

The device is the perfect instrument for physiotherapists carrying out treatments in a wide range of medical facilities or active in sports medicine. Thanks to its dimensions, light weight and dedicated bag to accommodate the apparatus and accessories, its transport is extremely easy. Additionally, it is possible to expand the device functionality with a battery module. It allows the device to work up to 4 hours without connection to a power source.

 

 

Modernity and ergonomics

The PhysioGo.Lite Laser unit is equipped with a 5-inch color display and a touch panel. The laser may be operated in manual or program mode. The applied innovative changes in the software mdake the device operation very intuitive. The device automatically calculates the duration of the treatment in relation to the power, dose, frequency and area of the therapeutic field.

 

At any time during the operation of the device, the user can check the statistics of the treatments carried out and the operating time of the individual low-energy laser therapy light sources.

Energy saving

The PhysioGo.Lite Laser has an energy-saving function. After an hour of inactivity, the device switches off preventing energy waste.

 

 

Dedicated mode for optical fiber applicators

In the case of point probes, the use of optical fibre applicators extends the therapeutic possibilities of the device. The PhysioGo.Lite Laser has a special mode implemented in the instrument’s software that ensures that the treatment time is adjusted to the type of fibre optic applicator used to deliver the correct amount of energy to the area being treated. As a result, it can be successfully used for laseropuncture or laser therapy procedures in ENT.

 

 

Treatment encyclopedia – predefined therapeutic procedures

175 built-in treatment programs illustrated by the treatment encyclopedia have been created to optimally adapt the parameters of low level laser therapy to the diseases of patients undergoing treatment. The therapist can choose a specific therapy from the device’s memory by searching for the name of the appropriate disease entity or use a division into fields such as: Orthopedics, Sports Medicine, Aesthetic Medicine, Rheumatology, Neurology, Dermatology, and Angiology. The user has the ability to create and save up to 200 own treatment programs in the PhysioGo.Lite Laser unit memory. The device also has predefined laser programs – 8 Nogier’s acupuncture programs and 30 Voll’s acupuncture programs.

Następny slajd

PhysioGo.Lite Laser

video manual

We invite you to watch the instructional video. From the video you will learn what the software looks like, how to set up the treatment, how to use the built-in encyclopedia of predefined programs as well as the basic operation of the device.

Play video
Następny slajd

Detailed technical specification

Features

product code

A-UL-AST-PLL

color display with touch panel

5"

independent treatment channels

1

manual mode of operation

disease entities selected by name or medical field

preset treatment programs database

possibility of creating user programs

favorite programs

possibility of program names edition

encyclopaedia describing the treatment methodology

treatment statistics

buzzer sound volume regulation

STANDBY mode

battery

optional

energy saving mode

optional

Laser therapy

operation with applicators: scanning laser, cluster laser and point probes

emission modes: continuous and pulse

regulation of laser power radiation

duty factor regulation

possibility of automatic treatment procedure repetition

automatic laser radiation power test

automatic calculation of time relative to treatment parameters - dose, power, duty factor, treatment area

three modes of treatment field irradiation in scanning laser applicators

dedicated modes for working with optic fiber applicators

optical fiber applicators for laserpuncture and ENT applications

pilot beam indicating the application site

Preset treatment programs

preset treatment programs, including:

IR point probe programs

39

R point probe programs

18

programs with Nogier frequency

8

programs with Voll frequency

30

cluster laser applicator programs

54

preset sequences for scanning laser applicators

26

user-defined programs

user-defined programs – biostimulation laser therapy

50 (for each applicator)

favorite programs

Laser therapy technical parameters

laser device class

3B

treatment timer

1 s - 100 minutes

Laser therapy parameters - biostimulation laser point probes

red light laser point probes wavelength

660 nm

maximum power of the red light point probes

80 mW

infrared laser point probes wavelength

808 nm

maximum power of the infrared point probes

400 mW

power regulation

25%, 50%, 75%, 100%

pulse mode frequency

1 - 5000 Hz

duty factor in pulse mode

10 - 90%, pulse 50 μs

Laser therapy parameters - scanning laser applicator

scanning laser applicator wavelength

808 & 660 nm

maximum power of the scanning laser applicator

450 & 100 mW

power regulation

50%, 100%

pulse mode frequency

1 - 5000 Hz

duty factor for scaning laser applicator pulse mode

75%

Laser therapy parameters - cluster laser applicator

cluster laser applicator wavelength

4x 808 nm & 5x 660 nm

maximum power of the cluster laser applicator

4x 400 mW & 5x 40 mW

power regulation

50%, 100%

pulse mode frequency

1 - 5000 Hz

duty factor in pulse mode

10 - 90%

General technical parameters

dimensions

25 x 27 x 16.5 cm

device weight

3 kg

battery type (option)

Li-ion

battery capacity (option)

2100 mAh

power supply

100-240 V, 50/ 60 Hz

See more
arrow

Other products from the Lite series

Biostimulation
laser therapy

In order to fully understand the effect of the laser biostimulation on tissues, special attention should be paid to the word “biostimulation”.

This website uses technical and functional cookies or internet analytical cookies, with your consent marketing cookies. You can read more about this in the Cookies Policy and the Information Clause. By accessing the website, you agree to them according to your browser settings. You can change them at any time, and if you do not do so, browsing the website will use these files.